Problem
This article walks through the steps necessary to resolve the "The program and the file vault are of incompatible versions" message. This message is usually a result of the vault database hosted by SQL Server not being upgraded after a PDM major release upgrade.
Solution
Use the Database Upgrade Wizard to upgrade the Vault Database with the steps below:
- This tool can be located in the Swpdmserver\Upgrade subfolder on the SOLIDWORKS DVD or the complete SOLIDWORKS installation package.
- Right-click on Upgrade.exe and select 'Run as administrator' to launch the application.
- Click "Yes" on the message box warning that the upgrade wizard should only be run by an administrator.
- Review and confirm all the prerequisites have been performed, then click "Next"
- Select the SQL Server instance from the drop-down list (if it is not listed, we can manually type it in) and click "Next"
- Enter a Username and Password for a user with sysadmin permissions on the SQL Server and click "Log In"
- Put a check mark next to the file vault databases that need to be upgraded and click "Next"
- Click "Next" again to start the upgrade
- Once the upgrade is finished, review the log to confirm each database was successfully upgraded, then click "Finish"
- After the upgrade, restart the Microsoft SQL Server. If we do not, we may experience performance drops until a restart is performed
For additional support, existing customers can submit a ticket or new customers can contact Hawk Ridge Systems.
Comments