Problem
When selecting a file in the SOLIDWORKS PDM Vault, a user may get a warning: "The current SOLIDWORKS Task Add-in version is unsupported". This may occur after upgrading the PDM Server and Client, where the task
add-in used by the PDM client machine may be corrupted or the wrong version.
Solution 1: Verifying the Task add-in version
Confirming the task add-in version on the PDM client can be done through the Task Host Configuration Manager. After the Task Host Configuration Manager loads, it will show if a task add-in is enabled for the selected vault.
- Navigate to the Windows task tray and right-click the blue/white icon for PDM
- Select 'Task Host Configuration' from the menu option
- Select the PDM Vault from the drop-down in the upper right-hand corner of the Task Host Configuration menu.
- Review the version of the Task Add-in. The format of the Version Number of the task add-in is TTSSBBBB, where TT is the Major Release Number, which is 8 more than the Version Year of SOLIDWORKS PDM, SS is the Service Pack, and BBBB is the Build Number. For the Task Add-in in the example below, the major release number is 31 (SOLIDWORKS PDM 2023), the Service Pack is 4, and the Build Number is 0047. Note: SOLIDWORKS PDM 2020 and older use different version terminology: YYYYSSBBBB, where YYYY is the Version Year 20XX, SS is the Service Pack, and BBBB is the Build Number.
- After verifying that the Task Add-in is the same version as the PDM Client, go to the next solution in this article. If the task add-in is not current, proceed to step 6 about upgrading the task add-ins.
- If the PDM Task Add-in is not the same version as the PDM Client, upgrade it by following the steps in this article: Updating SOLIDWORKS PDM Add-ins – Hawk Ridge Systems Support
Solution 2: Renaming the PDM Plugins Cache Folder
The PDM Client stores plugins in a cache folder located in the hidden AppData folder directory in Windows. This cache folder can become corrupt and cause warnings regarding the add-in and impact functionality.
- Navigate to the PDM directory: c:\users\<username>\AppData\Local\SolidWorks\SOLIDWORKS PDM. Note: This folder may be hidden by default in Windows File Explorer. In Windows 11, go to View > Show > Hidden Items. In Windows 10 & older, go to the View Tab and check the "Hidden Items" option.
- Select the plugins folder and rename it to "Plugins_old"
- Log off from the PDM Vault and then log back in
- Open the PDM Vault to check if the issue has been resolved
For additional support, existing customers can submit a ticket or new customers can contact Hawk Ridge Systems.